Company Profile Contact Us
New Products
                     


Pro 100 & Pro 200 Series CCD IFDs


Portable ProLocator Fire Sniffer
Aqua Alert Water Leak Detector
ThermoCable Linear Heat Detection Wire

 



ProSeries CCD Early Warning Fire Detection Systems

If you are looking for a better alternative to laser based early warning fire detection, you'll find it in the SAFE ProSeries line of "Cloud Chamber Detection" (CCD) technology Incipient Fire Detection (IFD) products. The wall mounting ProSeries early warning fire detectors (and portable ProLocator "Fire Sniffer") detect pre-smoke particles of combustion that are produced at the earliest incipient stage of a fire, and they are complete unaffected by dust and other airborne particulate.


IFD Cirrus ProSeries CCD Hybrid Air Sampling IFD Detectors

  • CCD Technology provides the earliest early warning fire detection

  • Immune to dust, dirt, heat, cold, humidity and other factors that typically cause False Alarms in other detectors

  • Large area coverage - up to 43,200 sq. ft with one panel

  • 0.0000% to 100% obs/ft, and more sensitivity combinations than any other air sampling detector

  • Drop in replacements for any air sampling detector WITHOUT sampling pipe modification

  • Less maintenance, and does not require costly periodic re-calibration
    *More new features and easier to operate

  • Less costly than other systems



    Download PDF document here

     

    Pro X4 Series CCD Technology IFD Products

     

    IFD Cirrus ProSeries Specifications

    Supply Voltage: 20 - 29 VDC

    Dimensions (WxHxD):

    PRO 100 Mini - 11.25" x 8.5 x 4.25"

    PRO 200 - 14.25" x10 x 4.5"

    PRO 200D - 14.25" x10 x 4.5"

    PRO 200DSC - 17" x 15 x 5.7"

    PRO X4 - 17.3" x 15.2" x 5.7

    Pipe length:

    PRO 100 Mini - Up to 325 ft.

    PRO 200 - 4 pipes up to 650 ft.

    PRO 200D - 4 pipes up to 650 ft.

    PRO 200DSC - 4 pipes up 650 ft.

    PRO X4 - Max. over 1400 ft.

    Sample Holes:

    PRO 100 Mini - Up to 50 holes per zone with 30"x30" spacing.*

    PRO 200, PRO 200D & PRO200DSC - Up to 100 holes per zone, with 30'x30" spacing.*

    Pro X4 - Up to 12 Sample Heads per Zone with 30' x 30' spacing, up to 4 Zones

    Alarm Levels: 4 Adjustable

    Variable Sensitivity Settings: Each zone has 10 possible sensitivity settings per alarm level. Each level can be changed 3 times per day and different f or each day of the week. Other Indications: Supply Healthy, Fault

    Sensitivity Range: 0.0000 to 100% obs./ft.

    Event Log: 200 events stored on FIFO basis

    ProSeries Options: CirrusPro Network, BMS Interface, Alarm Panel Protocol

    Download PDF document here

     

    ProLocator "Fire Sniffer" Portable CCD Hybrid Air Sampling Detector

    Early warning fire detection is important, but how do you find the source of the alarm? The ProLocator Fire Sniffer is the world's ONLY portable CCD early warning fire detector that allows you to "sniff" out the source of the fire or pre-fire event. The ProLocator Fire Sniffer uses "Cloud Chamber Detection" (CCD) Technology that detects particles of combustion. Similar in operation to a Gieger Counter, the ProLocator Fire Sniffer directs you to the source of the fire with audible and visual indicators. Identifying the source of your early warning fire alarm has never been easier.

    Sensitivity Range: 0.0000 to 100% obs./ft.

    Power: Battery operated with charger

    Dimensions (WxHxD): 12" x 11" x 4.25"

    Weight: 12 lbs.

    Unit Operating Temperature: 32° - 130°F (0 - 54°C)

    Location Indicator: LED and audible

    Other Indicators: Supply Health and Fault

     

    Download PDF document here

     

    AquaAlert Water Detection Systems
    AquaAlert Water Detection Systems make easy work of letting you know promptly when a water leak has occurred. AquaAlert is available in both "Spot" and "linear" water leak detection and we can supply the system with a custom graphic annunciator that will identify the location of the water detection.

    Area of Detection: Wire = Max. 5000 ft sq. Per zone (Based on 15' centers)

    Spot Detector (For use in areas water will collect E.G. Sumps/Drains)

    Number of Zones: Up to 4 (Single Zone , Four Zone or Single Zone Distance Locating)

    Maximum Wire Lengths: 1000' ( We recommend 500' to keep zones size manageable)

    Wire Spacing: 5', 10' or 15' On Center

    Power Input: 115VAC, 60Hz, .5 amps

    Battery Back Up: 12 VDC 1.2 amp/hr. Battery With automatic charger

    Indicators: LED type: for Alarm, Trouble and Power-on Status

    Distance Locating Type: Digital Display (Footage measurement)

    Size: 10" x 10" x 4" (254mm x 254mm x 102mm

    Contact Ratings: 1 Zone Unit - 1 Relay (Alarm and Fault Combined)
    2 - 8 Zone Unit - 2 Relays - Alarm and Fault


    Spot Detector can be connected to any type of warning device to alert you of water-based leakage. The Spot Detector can also identify the location of the problem to help you quickly make repairs.

    Download PDF document here

     

    ThermoCable Linear Heat Detection Wire
    SAFE Fire Detection, Inc. ThermoCable Linear Heat Detection Wire offers longer operating distances and greater ease of installation over competitive linear heat detection products. It can be used with any certified fire alarm panel and ThermoCable offers you savings on both the cost of the wire and the cost of installation. ThermoCable is available in a variety of alarm temperatures and it carries full FM, UL and ULC certifications, among others. It's simple; a better linear heat detection wire at a better price.

    ThermoCable Linear Heat Detection Wire
    ThermoCable is a real breakthrough in linear heat detection wire. With a dramatically lower resistance/ft. over competitive products, ThermoCable allows for runs of up to 10,000' in a single zone and the more flexible, yet rugged construction of ThermoCable makes installation easier and less time consuming.

    ThermoCable is certified by UL, ULC and FM for use with ANY FIRE DETECTION PANEL. You don't have to purchase the Fire Detection Panel from SAFE Fire Detection, Inc.!

  • Lower cost
  • Up to 10,000 linear feet of ThermoCable™ per zone, .05 ohms/ft resistance per twisted pair wire (Lower than any other wire)
  • Compatible with ALL Fire Alarm Control / Releasing Panels (Maximum length determined by resistance allowed by panel)
  • Multiple alarm temperatures: 155°F, 172°F, 190°F, 220°F, 280°F, 360°F
  • Distance locating available
  • Can detect anywhere along the entire length of wire
  • Multiple alarm temperatures can be mixed on the same zone
  • Total zone length replacement unnecessary after alarm
  • Longer standard spool lengths means less splicing
  • Custom lengths available
  • Corrosion and UV resistant
  • A full assortment of mounting and splicing hardware available
    Download PDF document here

     

    Model 4410 Fire Alarm Control/Releasing Panel
    The TC4410 Panel is a microprocessor based multi-hazard fire alarm control /releasing panel for use on pre-action and deluge type sprinkler systems. The TC4410 is U/L and ULC Listed (TC4410A), FM, MEA and CSFM approved and complies with UL Standard 864 for Local Control Units for Releasing Service. It is designed to be compatible with the requirements of NFPA-72, NFPA-13, NFPA-15 and NFPA-16.

    The TC4410 Fire Alarm Control/Releasing Panel may be used with ThermoCable™ linear heat detection and providing up to 10,000 linear feet of detection wire per zone. The TC4410 is also capable of up to 25 initiating devices such as photo/electric, ionization, heat, UV/IR or beam detectors per zone. It may also be used with flow and tamper switches for a complete detection and suppression system.

  • Four Zone Panel, Class A or B
  • Self Diagnostics circuitry for system supervision
  • 32 character alpha-numeric LCD Display
  • Custom banner message text
  • Custom zone description text
  • Monitors up to 25 smoke detectors per zone
  • Pre-action/deluge sprinkler release, smoke detection, flow and tamper monitoring and annunciation
  • Releasing circuits protected from false activation
  • Continuous or timed discharge
  • Alarm, trouble and supervisory relays
  • Available in NEMA enclosures to suite any application
  • 24, 60 or 90 hour battery backup
  • Complies with UL 864

     

    About this Product:

    Manufacturer's Website: http://www.safefiredetection.com/

    Products downloads (PDF)
  • Hybrid Air Sampling IFD
  • CCD Technology IFD Products
  • IFD Cirrus ProSeries
  • ProLocator "Fire Sniffer"
  • Aqua Alert Water
    Leak Detector
  • SAFE ThermoCable Application Guide

     




     

     

     

     

    © 2004 Detection & Measurement Systems, Inc. 10101 Southwest Frwy, #570     Houston, TX 77074