Fire Sentry Corporation Optical Flame
Detection & Digital Video Smoke Detection
Fire Sentry Corporation electro-optic digital fire detectors are
highly sophisticated devices that sense the optical radiant energy
emitted by fires. The on-board microprocessor employs complex Digital
Signal Processing (DSP) to accurately tell the difference between
radiant energy of a real fire and a false source. The decision making
process involves thousands of calculations to insure reliable detection
without false alarms.
Digital Video Smoke Detection (DVSD), from Fire Sentry Corporation,
is based on sophisticated analysis of video images received from
multiple CCTV cameras, allowing the system to actually "see"
smoke from an incipient fire. This provides early fire detection
with visual verification. With up to 80 detection zones, DVSD offers
large area monitoring with unparalleled features.
FS24 "Quad-Band" Triple IR Plus (IR/IR/IR/Visible) Flame Detector
|
|
Patented WideBand™ Infrared
Technology |
|
|
Visible Sensor for optimum
false alarm rejection |
|
|
Selectable Long Range Detection
(Over 200’ for 1 sq. ft. heptane fire) |
|
|
Wide 110° cone-of-vision |
|
|
Dual Microprocessors for reliable
performance |
|
|
Real World Clock |
|
|
FirePic™ Pre-Fire Event
Data Storage |
|
|
Event log with Date and Time
Stamp |
|
|
RS-485 Modbus Communication |
|
|
Isolated 4-20 mA Analog output
(sink or source) |
|
|
Alarm, Fault and user selectable relays. |
|
|
Optical and Electronic Self-Test |
|
|
Widest Operating Temperature Range |
|
|
Patented Electronics Module provides components protection
with easy plug-in terminations and field installation |
|
|
FM Class 1, Division 1, Groups B, C and D |
|
|
FS18 TriBand (IR/IR/Visible) Flame Detector
|
|
Patented WideBand™ Infrared
Technology |
|
|
Visible Sensor for optimum
false alarm rejection |
|
|
Selectable Long Range Detection
(60’ for 1 sq. ft. heptane fire) |
|
|
Wide 110° cone-of-visionn |
|
|
Dual Microprocessors for reliable
performance |
|
|
Real World Clock |
|
|
FirePic™ Pre-Fire Event Data
Storage |
|
|
Event log with Date and Time
Stamp |
|
|
RS-485 Modbus Communication |
|
|
Isolated 4-20 mA Analog output
(sink or source) |
|
|
Alarm, Fault and user selectable relays. |
|
|
Optical and Electronic Self-Test |
|
|
Widest Operating Temperature Range |
|
|
Patented Electronics Module provides components protection
with easy plug-in terminations and field installation |
|
|
FM Class 1, Division 1, Groups B, C and
D |
|
|
SS4-A Multi-Spectrum (UV/IR/Visible) Flame Detector
|
|
Patented WideBand Infrared Technology |
|
|
Visible Sensors for optimum
false alarm rejection |
|
|
15', 30', 45' and 60' Detection
Ranges (1 sq. ft. heptane fire) |
|
|
Wide 120° cone-of-vision |
|
|
FirePic Pre-Fire Event
Data Storage |
|
|
RS-485 FireBus Communication |
|
|
4-20 mA Analog output (source) |
|
|
Alarm, Fault and Alarm Verification
relays |
|
|
Optical and Electronic Self-Test |
|
|
Widest Operating Temperature
Range |
|
|
FM/CSA/ATEX/GOST Class 1, Division
1, Groups B, C and D |
|
|
FS7 Multi-Spectrum (IR/IR/Visible) Flame Detector
|
|
Semiconductor Clean Room Optical Flame Detector |
|
|
Patented WideBand Infrared
Technology |
|
|
Visible Sensor for optimum
false alarm rejection |
|
|
Not Sensitive to Background
Radiant Energy |
|
|
Not Affected by Absorbing Smoke,
Gasses or Chemical Vapors |
|
|
Unique 2-Stage Fire Detection
Response |
|
|
Wide 120° cone-of-vision |
|
|
FirePic Pre-Fire Event
Data Storage |
|
|
RS-485 FireBus Communication |
|
|
Rugged IP67 Leak-Proof Polypropylene
Housing |
|
|
Alert, Alarm and Fault relays
or RS485 FireBus Output |
|
|
Optical and Electronic Self-Test |
|
|
Wide Operating Temperature
Range |
|
|
FM Approved for Wet Bench and
Clean Room Applications |
|
| |
| |
FS10 Multi-Spectrum (IR/IR/Visible) Flame Detector
|
|
Automatic Electrostatic Paint Spray Booth Optical
Flame Detector |
|
|
Patented WideBand Infrared
Technology |
|
|
Visible Sensor for optimum
false alarm rejection |
|
|
Not Sensitive to Background
Radiant Energy |
|
|
Not Affected by Absorbing Smoke,
Gasses or Chemical Vapors |
|
|
Unique 2-Stage Fire Detection
Response |
|
|
Wide 120° cone-of-vision |
|
|
FirePic Pre-Fire Event
Data Storage |
|
|
RS-485 FireBus Communication |
|
|
Alert, Early Warning, Alarm
and Fault relays or RS485 FireBus Output |
|
|
Optical and Electronic Self-Test |
|
|
Wide Operating Temperature
Range |
|
|
FM Approved Class 1, Division
1, Groups B, C and D |
|
|
Digital Video Smoke Detection
(DVSD)
|
|
Fast, Early Response to a Potential Fire
|

|
|
|
Utilizes Existing CCTV Surveillance
Cameras |
|
|
No Size Restriction on Detection
Zones |
|
|
On-Screen Visual Verification |
|
|
False Alarm Immunity Algorithms |
|
|
Up to 8 Cameras / 80 Detection
Zones per System |
|
|
First Detection System to Alarm
at the Fire Source |
|
|
Indoor and Outdoor Use |
|
|
Long Range Detection and Large
Area Coverage |
|
|
Unaffected by Extreme Weather
and Temperatures |
|
|
Digital Alarm Image Storage
to Hard Disk |
|
|
16 Opto-Isolated Relay Outputs |
|
|
Cameras can be mounted Outside
of Hazardous Areas |
|
|
FM Approved |

|
|